Change order of F103C8 clock options to ensure 72 MHz defaults. #944
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
After merging a PR #878 the option "HSI 64 MHz" was added to the first place in the list of clock frequency options for the F103C8 bluepill and therefore became the default setting after changing the board.
This leads to confusion, since for most users, the standard clock option of the bluepill board is "72MHz (Normal)". Also many libraries and existing projects are designed for using with 72 MHz clock option.
This PR simply swaps the F103C8 clock options to restore 72 MHz clock as the default choice.